External Exhaust Valve Units G3-ME
Prevent the malfunction of air leak testers by preventing the invasion of water and oil with external exhaust valve units!
When water or oil are left inside work, or it is used in a testing device which is used in combination with water-dunking, these foreign substances might get into the air leak tester exhaust, and it might cause a malfunction. By setting up the exhaust valve unit close to the work, the malfunction can be prevented before it happens. It adopted an air-operated valve with a special structure which is resistant to solid waste. The movement of the exhaust valve can be controlled by the tester body.
Specifications of G3-ME
Maximum pressure:800 kPa
Withstand pressure:1.0 MPa
Connection bore:Rc1/4
Pilot pressure:400 ~700kPa(Supply from leak testers)
Accessories:Tube for pilot pressure External diameter4mm Length3 m
External dimensions:W116, L110, H100 mm including fixed metal fittings and installation part.
Handling leak testers:Low and medium pressure leak testers for external exhaust valve
Contact Us
Please feel free to contact us via the form below.
Loading...