Master Chamber MC series

Eliminate error factors of leak measurement by the adjustment matched with the heat change characteristics of work!
When putting test pressure on work, the air temperature rises rapidly by insulation change, and it will be an error factor of minute leak measurement. Master Chamber can match the temperature characteristics of work by changing the ratio of volume and surface area with the number and arrangement of fins and eliminate error factors by temperature change. It enables measurements excellent in repeatability without volume change.

Advantages for using the Master Chamber
●Adjustable, matching with heat change characteristics of work
●Small design, and it can be set up at any place
●The cost can be reduced, compared with producing a Master using work.
●It is excellent in airtightness as it is sealed tightly with an o-ring, so we can use it at ease for a long time.
●Realize the measurement excellent in repeatability without volume change
●If using Mastering with a Master Chamber, we can use the common Master Chamber in multiple works and do not need to change the Master.

Contact Us

Please feel free to contact us via the form below.
Loading...